Related Experiment Video
Updated: Dec 12, 2025

Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
Diagnosis of atrial fibrillation based on arterial pulse wave foot point detection using artificial neural networks
Unai Zalabarria1, Eloy Irigoyen1, Andrew Lowe2
1Department of Systems Engineering and Automation, Faculty of Engineering of the UPV/EHU, Bilbao, 48013, Spain.
Background:
Atrial fibrillation (AF) is a common arrhythmia that is strongly related to the risk of stroke. Some methods in the literature approach AF diagnosis based on cardiovascular signals of several minutes in length. However, many traditional methods utilized to monitor health status in terms of AF rely on electrocardiograms, which are time consuming and require specialized equipment to collect. By contrast, more practical systems focus on noninvasively collected short-term cardiovascular signals, such as arterial pulse waveforms (APWs).
Methods:
In this paper, an AF diagnosis algorithm based on the processing of parameters extracted from short-length heart period (HP) measures is proposed. The HP is obtained by locating foot points (FPOs) in 10-second epochs of APW signals. The algorithm consists of two main stages. First, five parameters representative of the APW morphology are extracted to train an artificial neural network (ANN) model for FPO detection. The moving interpolation difference method and an improved second derivative maximum method are employed for APW parameter extraction. Second, 13 temporal-domain, frequency-domain and nonlinear HP parameters are extracted from the previously identified FPOs. These are subsequently orthogonalized using principal component analysis to train a second ANN for effective AF diagnosis.
Results:
Both ANNs were trained and validated on a labeled data set with 20-fold cross-validation, achieving a mean sensitivity and specificity of 97.53% and 90.13%, respectively, for AF diagnosis and an F1 score of 99.18% for FPO identification.
Conclusions:
This paper presents a validated solution for the diagnosis of AF from APW records using parameters derived from HP measures. In addition, compared to that of a commercial BP+ device, improved FPO detection performance is achieved, making the proposed algorithm a strong candidate for the automatic detection of FPOs in oscillometric devices.
Related Concept Videos
Pulse Assessment Sites
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse
The pulse serves as a clinical...
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Special considerations while measuring pulse
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: