Related Experiment Video
Updated: Dec 12, 2025

The Use of Mixed Reality in Custom-Made Revision Hip Arthroplasty: A First Case Report
Published on: August 4, 2022
Routine Fracture Fixation for a Periprosthetic Hip Fracture Below Birmingham Hip Resurfacing: A Case Report
Jordy van Rijn1, Maarten C Koper2, Pieter K Bos1
1Department of Orthopaedics, Erasmus Medical Center, Rotterdam, the Netherlands.
Case:
We present a case of a 56-year-old man who sustained a basal cervical periprosthetic fracture around a well-fixed metal-on-metal hip resurfacing arthroplasty (MoMHRA). Although several fixation methods have been described, there seems to be no consensus about the optimal fixation method for fractures around MoMHRAs. This fracture could be regarded as a Vancouver type-B1 or -C periprosthetic fracture, so we successfully treated our patient in a standard way with a dynamic hip screw (DHS) and one cannulated hip screw.
Conclusion:
We describe DHS fixation as a successful treatment option for periprosthetic hip fractures around well-fixed MoMHRA.