Related Experiment Video
Updated: Dec 12, 2025

Using Q Suture to Enhance Resistance to Gap Formation and Tensile Strength of Repaired Flexor Tendons
Published on: June 3, 2020
Tensile strength and early healing of self-locking and surgeon's knots
Kathleen M Weatherall1, Lindsey H Boone1, Fred J Caldwell1
1Department of Clinical Sciences, Auburn University College of Veterinary Medicine, Auburn, Alabama, USA.
Objective:
To compare the biomechanical properties and healing of ventral midline celiotomies (VMC) closed with a self-locking knot combination and forwarder start and Aberdeen end (F-A) vs a traditional knot combination and surgeon's start and end (S-S).
Study Design:
In vivo, experimental.
Animals:
Twenty-one horses.
Methods:
Fourteen horses underwent VMC, which was closed with either an F-A (n = 7) or an S-S (n = 7) knot combination. Incisions were subjectively graded by masked evaluators for dehiscence, edema, and drainage. Biomechanical testing was performed on three abdominal segments, and histology was performed on one segment from each animal after humane euthanasia 10 days post-VMC. The abdominal wall of control horses (n = 7, no celiotomy) was collected for biomechanical testing.
Results:
Forwarder start and Aberdeen end and S-S horses had less tensile strength compared with control horses (P ≤ .001). No differences were detected between treatment groups for any variable evaluated, including tensile strength (P = .975), location of failure (P = .240), and histologic healing at the knot (P = .600).
Conclusion:
Closure of VMC with self-locking knots resulted in biomechanical and healing features similar to those with a traditional closure technique, with neither restoring the tensile strength of the linea alba.
Clinical Significance:
Results of this study provide evidence to support a clinical trial to evaluate long-term performance of the F-A self-locking knot closure in horses.
Related Concept Videos
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Posttensioned Masonry Walls
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...