An open-source automated algorithm for removal of noisy beats for accurate impedance cardiogram analysis
Shafa-At Ali Sheikh1,2, Amit Shah3,4,5, Oleksiy Levantsevych3
1Department of Biomedical Informatics, Emory University, Atlanta, GA, United States of America.
Objective:
The impedance cardiogram (ICG) is a non-invasive sensing modality for assessing the mechanical aspects of cardiac function, but is sensitive to artifacts from respiration, speaking, motion, and electrode displacement. Electrocardiogram (ECG)-synchronized ensemble averaging of ICG (conventional ensemble averaging method) partially mitigates these disturbances, as artifacts from intra-subject variability (ISVar) of ICG morphology and event latency remain. This paper describes an automated algorithm for removing noisy beats for improved artifact suppression in ensemble-averaged (EA) ICG beats.
Approach:
Synchronized ECG and ICG signals from 144 male subjects at rest in different psychological conditions were recorded. A 'three-stage EA ICG beat' was formed by passing 60-seconds non-overlapping ECG-synchronized ICG signals through three filtering stages. The amplitude filtering stage removed spikes/noisy beats with amplitudes outside of normal physiological ranges. Cross-correlation was applied to remove noisy beats in coarse and fine filtering stages. The accuracy of the algorithm-detected artifacts was measured with expert-identified artifacts. Agreement between the expert and the algorithm was assessed using intraclass correlation coefficients (ICC) and Bland-Altman plots. The ISVar of the cardiac parameters was evaluated to quantify improvement in these estimates provided by the proposed method.
Main Results:
The proposed algorithm yielded an accuracy of 96.3% and high inter-rater reliability (ICC > 0.997). Bland-Altman plots showed consistently accurate results across values. The ISVar of the cardiac parameters derived using the proposed method was significantly lower than those derived via conventional ensemble averaging method (p < 0.0001). Enhancement in resolution of fiducial points and smoothing of higher-order time derivatives of the EA ICG beats were observed.
Significance:
The proposed algorithm provides a robust framework for removal of noisy beats and accurate estimation of ICG-based parameters. Importantly, the methodology reduced the ISVar of cardiac parameters. An open-source toolbox has been provided to enable other researchers to readily reproduce and improve upon this work.
More Related Videos
10:23Equipment Setup and Artifact Removal for Simultaneous Electroencephalogram and Functional Magnetic Resonance Imaging for Clinical Review in Epilepsy
Published on: June 23, 2023
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Bode Plots Construction
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....