Related Experiment Video
Updated: Dec 12, 2025

Peptide and Protein Quantification Using Automated Immuno-MALDI iMALDI
Published on: August 18, 2017
Using Two Peptide Isotopologues as Internal Standards for the Streamlined Quantification of Low-Abundance Proteins by
Sahar Ibrahim1, Bjoern C Froehlich2, Adriana Aguilar-Mahecha3
1Segal Cancer Proteomics Centre, Lady Davis Institute, Jewish General Hospital, McGill University, Montréal, Québec H3T 1E2, Canada.
Abstract:
Mass spectrometry (MS), particularly targeted proteomics, is increasingly being used for quantifying specific proteins and peptides in clinical specimens. The coupling of immuno-enrichment of proteotypic peptides with MS [e.g., immuno-multiple reaction monitoring (MRM) and immuno-matrix-assisted laser desorption ionization (MALDI)] enables the development of highly sensitive and specific assays for low-abundance signaling proteins. By incorporating stable isotope-labeled standards, these workflows allow the determination of endogenous protein concentrations. This is typically achieved through external calibration, often using surrogate matrices, which has inherent limitations for the analysis of clinical specimens as there are often substantial variations in the sample matrix, and sample amounts are typically limited. We have previously introduced the use of two peptide isotopologues for generating external calibration curves in plasma. Here, we present a two-point internal calibration (2-PIC) strategy using two isotopologues for immuno-MS assays and demonstrate its flexibility and robustness. Quantification of the tumor suppressor PTEN in Colo-205 cells by immuno-MRM and immuno-MALDI using 2-PIC and external calibration yielded very similar results (relative standard deviation between 2-PIC and external calibration: 4.9% for immuno-MRM; 1.1% for immuno-MALDI), without the need for a surrogate matrix or additional patient material for calibration, while concurrently reducing the instrument time and cost. Although our PTEN immuno-MRM and immuno-MALDI assays can be considered to be orthogonal as they utilized entirely different sample preparation and MS analysis workflows, targeted different PTEN peptides, and were performed in different laboratories, the endogenous Colo-205 PTEN levels determined with 2-PIC showed a good correlation (r2 = 0.9966) and good agreement (0.48 ± 0.01 and 0.29 ± 0.02 fmol/μg of total protein) between immuno-MRM and immuno-MALDI.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...