Related Experiment Video
Updated: Dec 12, 2025

Erythrocyte Sedimentation Rate: A Physics-Driven Characterization in a Medical Context
Published on: March 24, 2023
On the Discretization of the Power-Law Hemolysis Model
Mohammad M Faghih1, Ahmed Islam2, M Keith Sharp1
1Biofluid Mechanics Laboratory, Department of Mechanical Engineering, University of Louisville, Louisville, KY 40292.
Abstract:
Flow-induced hemolysis remains a concern for blood-contacting devices, and computer-based prediction of hemolysis could facilitate faster and more economical refinement of such devices. While evaluation of convergence of velocity fields obtained by computational fluid dynamics (CFD) simulations has become conventional, convergence of hemolysis calculations is also essential. In this paper, convergence of the power-law hemolysis model is compared for simple flows, including pathlines with exponentially increasing and decreasing stress, in gradually expanding and contracting Couette flows, in a sudden radial expansion and in the Food and Drug Administration (FDA) channel. In the exponential cases, convergence along a pathline required from one to tens of thousands of timesteps, depending on the exponent. Greater timesteps were required for rapidly increasing (large exponent) stress and for rapidly decreasing (small exponent) stress. Example pathlines in the Couette flows could be fit with exponential curves, and convergence behavior followed the trends identified from the exponential cases. More complex flows, such as in the radial expansion and the FDA channel, increase the likelihood of encountering problematic pathlines. For the exponential cases, comparison of converged hemolysis values with analytical solutions demonstrated that the error of the converged solution may exceed 10% for both rapidly decreasing and rapidly increasing stress.
Related Concept Videos
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Design Example: Creating a Hydraulic Model of a Dam Spillway
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Parameters Affecting Nonlinear Elimination: Zero-Order Input, First-Order Absorption and Two-Compartment Model
When a drug is administered through a constant intravenous infusion and eliminated via nonlinear pharmacokinetics, it follows zero-order input. For example, oral drugs undergo first-order absorption upon administration and are eliminated through nonlinear pharmacokinetics.
In the case of subcutaneously administered drugs,...
Theories of Dissolution: The Danckwerts' Model and Interfacial Barrier Model