Related Experiment Video
Updated: Dec 11, 2025

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
A green - high throughput -extraction method based on hydrophobic natural deep eutectic solvent for the determination
Diogo C Morelli1, Gabrieli Bernardi1, Lucas Morés1
1Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, SC 88040-900, Brazil.
Abstract:
This study reports the use ofa natural deep eutectic solvent (NADES) with hollow fiber-microporous membrane liquid-liquid microextraction (HF-MMLLE) for the multiclass determination of 11 compounds classified as emerging contaminantsin water. Different deep eutectic solvents were synthetized and Thymol: Camphor (1:1 molar fraction) wasused as extraction solvent. The Thymol:Camphor was impregnated into the polypropylene membrane porous for 10 min, replacing commonly used solvents (ex. hexane and octanol). The optimized parameters were obtained by multi and univariate models. Extractions were carried out for 50 min using 1.5 mL of water sample at pH 6 and without addition of salt while desorption was made in a mixture of acetone: methanol (3:1, v/v) for 15 min. Separation/quantification was conducted by HPLC with a diode array detection (DAD)and calibration curves were obtained for each analyte. Determination coefficients higher than 0.9906 and limits of detection ranged from 0.3 to 6.1 µg L-1. Intraday precision (n = 3) ranged from 1.6 to 18.4% and inter day from 5.0 to 21.3%. Relative recoveries were performed in tap and stream water and ranged from 64 to 123%.
More Related Videos
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
12:11A Modified EPA Method 1623 that Uses Tangential Flow Hollow-fiber Ultrafiltration and Heat Dissociation Steps to Detect Waterborne Cryptosporidium and Giardia spp.
Published on: July 9, 2012
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Electrophoresis: Overview
There...