A Comparison Between Monofocal and Multifocal Intraocular Lenses in the Influence of Pupil Dilation on Target
Takeshi Teshigawara1,2,3, Akira Meguro3, Nobuhisa Mizuki3
1Yokosuka Choo Eye Clinic, Yokosuka, Kanagawa, Japan.
Purpose:
The aim of this study was to compare the influence of pupil dilation on power calculation formulas for third- (Hoffer Q, SRK/T) and fourth- (Haigis, Holladay3) generation intraocular lens (IOL) between monofocal and multifocal IOLs.
Design:
Retrospective, comparative study.
Methods:
We analyzed 280 eyes (162 monofocal, 118 multifocal; mean patient age: 72.9 ± 7.7 years; 41.25% male). Anterior chamber depth (ACD) and lens thickness (LT) were measured. Predicted postoperative refraction (PPR) and recommended IOL power were calculated using third- and fourth-generation formulas pre- and post-dilation. We evaluated the mean absolute change (MAC) in PPR, change in recommended IOL power per formula, and mean change in ACD and LT between pre- and post-dilation, for both monofocal and multifocal IOLs.
Results:
ACD and LT showed significant changes post-dilation. The MAC in PPR was significantly higher with fourth-generation formulas than that with third-generation formulas, for both IOLs, and more so for multifocal IOLs. For both IOLs, the PPR change correlated positively with ACD changes, but negatively with LT changes, for fourth-generation formulas. Multifocals correlated significantly stronger with LT than monofocals. When using fourth-generation formulas post-dilation, the recommended IOL power changed more frequently in multifocals than in monofocals, although not significantly.
Conclusions:
Pupil dilation did not influence third-generation formula calculations for both IOL types, but did affect PPR and recommended IOL power when using fourth-generation formulas, and more so for multifocals. Considering pupil dilation effects on monofocal and multifocal parameters is vital for accurate IOL calculation.
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...