Related Experiment Video
Updated: Dec 11, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Development and Validation of an LC-MS-MS Method for the Detection of 40 Benzodiazepines and Three Z-Drugs in Blood
Szabolcs Sofalvi1, Eric S Lavins1, Claire K Kaspar1
1Toxicology Department, Cuyahoga County Medical Examiner's Office (CCMEO), 11001 Cedar Avenue, Cleveland, OH 44106, USA.
Abstract:
An analytical method for the detection of 40 benzodiazepines, (±)-zopiclone, zaleplon and zolpidem in blood and urine by solid-phase extraction liquid chromatography-tandem mass spectrometry was developed and validated. Twenty-nine of 43 analytes were quantified in 0.5 mL whole blood for investigating postmortem, drug-facilitated sexual assault (DFSA) and driving under the influence of drugs cases (DUID). The four different dynamic ranges of the seven-point, linear, 1/x weighted calibration curves with lower limits of quantification of 2, 5, 10 and 20 μg/L across the analytes encompassed the majority of our casework encountered in postmortem, DFSA and DUID samples. Reference materials were available for all analytes except α-hydroxyflualprazolam, a hydroxylated metabolite of flualprazolam. The fragmentation of α-hydroxyflualprazolam was predicted from the fragmentation pattern of α-hydroxyalprazolam, and the appropriate transitions were added to the method to enable monitoring for this analyte. Urine samples were hydrolyzed at 55°C for 30 min with a genetically modified β-glucuronidase enzyme, which resulted in >95% efficiency measured by oxazepam glucuronide. Extensive sample preparation included combining osmotic lysing and protein precipitation with methanol/acetonitrile mixture followed by freezing and centrifugation resulted in exceptionally high signal-to-noise ratios. Bias and between-and within-day imprecision for quality controls (QCs) were all within ±15%, except for clonazolam and etizolam that were within ±20%. All 29 of the 43 analytes tested for QC performance met quantitative reporting criteria within the dynamic ranges of the calibration curves, and 14 analytes, present only in the calibrator solution, were qualitatively reported. Twenty-five analytes met all quantitative reporting criteria including dilution integrity. The ability to analyze quantitative blood and qualitative urine samples in the same batch is one of the most useful elements of this procedure. This sensitive, specific and robust analytical method was routinely employed in the analysis of >300 samples in our laboratory over the last 6 months.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024