Related Experiment Video
Updated: Dec 11, 2025

Identification and Protection of the Recurrent Laryngeal Nerve during Transoral Robotic Thyroidectomy
Published on: October 24, 2025
Predictors of Increased Surgical Drain Output following Type I Thyroplasty for Glottic Insufficiency
Nicholas R Lenze1, Ameer Ghodke1, Rupali N Shah2
1Department of Otolaryngology-Head and Neck Surgery, University of School of Medicine, Chapel Hill, North Carolina, U.S.A.
Objective:
To determine predictors of increased drain output following type I thyroplasty for glottic insufficiency.
Study Design:
Retrospective chart review.
Methods:
A retrospective review was conducted for patients who underwent type I thyroplasty for glottic insufficiency from 2014-2019. The primary outcome was 24-hour drain output. Increased drain output was defined as >50th percentile for the sample. Univariate logistic regression models and linear regression models were used.
Results:
There were 84 patients with a mean age of 58.9 (SD 16.9) years. Twenty-four-hour drain output ranged from 0 to 29 mL with a mean of 9.47 (SD 6.49) mL. Patients with a history of tobacco use (OR 3.33; 95% CI, 1.24-8.95; P = .017) and prior neck surgery (OR 3.52; 95% CI, 1.26 to 9.83; P = .016) were significantly more likely to have increased drain output following surgery; these patients had a mean increase in 24-hour drain output of 3.51 mL (95% CI, 0.52 to 6.51; P = .022) and 1.74 mL (95% CI, -1.41 to 4.89; P = .274), respectively. Type of implant (Gore-Tex vs. Silastic; P = .425) and operative technique (unilateral vs. bilateral; P = .506) were not significantly associated with drain output.
Conclusion:
History of tobacco use and prior surgery of the neck predict increased drain output following type I thyroplasty surgery. These patients may derive the most benefit from surgical drain placement. More research is needed to confirm these findings and elucidate potential mechanisms.
Level Of Evidence:
4 Laryngoscope, 131:1557-1560, 2021.
Related Concept Videos
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Tracheostomy Suctioning II: Procedure

