Related Experiment Video
Updated: Dec 11, 2025

Dosimetry for Cell Irradiation using Orthovoltage 40-300 kV X-Ray Facilities
Published on: February 20, 2021
Technical Note: Patient-weight dependence of the effective dose conversion coefficients for diagnostic x-ray imaging
Vladislav Golikov1, Polina Druzhinina1
1St-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev, Mira str. 8, St-Petersburg, 197101, Russian Federation.
Purpose:
The aim of this study was to provide a method and reference data for the evaluation of the weight dependence of the conversion coefficients from air collision kerma integrated over beam area to the effective dose for patients undergoing diagnostic x-ray examinations.
Method:
A simple physics-based analytical model was developed in order to calculate the weight dependence of the effective dose conversion coefficients based on existing values of the conversion coefficients between patient effective dose and air collision kerma integrated over beam area calculated by the Monte Carlo method on the base of computational MIRD-5-type stylized models.
Results:
The analytical expressions that make possible taking into account a patient's weight when assessing the effective dose were presented. The following categories of diagnostic x-ray examinations are considered: CT; plain radiography; cardiac angiography; fluoroscopy. The results indicate that the weight dependence of the effective dose conversion coefficients for different categories of diagnostic x-ray examinations has the same form. Correction factor for evaluation of the new value of the effective dose conversion coefficient for a patient with weight Wpa. when we know its value for a standard patient with weight Wst. depends on the ratios of their weights (Wst. /Wpat. ) and fractions of the incident energy which is imparted to a patient.
Conclusions:
The paper presents an approach and necessary data for the estimation of the weight dependence of the effective dose conversion coefficients for patients undergoing different diagnostic x-ray examinations.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Biological Effects of Radiation
X-ray Imaging
Radiological Investigation I: X-ray and CT
Drug Dosing: Obese Patients
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...