Electrolyte measurements differ between point-of-care and reference analysers in dogs with hypoadrenocorticism
S Fowlie1, S Spence2, E Roberts3
1Small Animal Hospital, University of Glasgow, Glasgow, G61 1QH, UK.
The Journal of Small Animal Practice
|August 20, 2020
Summary
Point-of-care analyzers for canine hypoadrenocorticism monitoring show discrepancies in electrolyte measurements compared to lab methods. These differences in sodium and chloride levels may impact treatment decisions for dogs.
Area of Science:
- Veterinary Medicine
- Clinical Pathology
- Canine Endocrinology
Background:
- Hypoadrenocorticism (Addison's disease) in dogs requires regular blood electrolyte monitoring.
- Point-of-care (POC) analyzers are commonly used for rapid electrolyte analysis in clinical practice.
- Medication dosages are adjusted based on POC electrolyte results.
Purpose of the Study:
- To evaluate the accuracy of two POC analyzers (IDEXX Catalyst Dx, IDEXX VetStat) against a reference laboratory method.
- To assess the measurement of sodium, potassium, chloride, and sodium:potassium ratios in dogs with hypoadrenocorticism.
- To investigate potential clinical implications of inaccurate POC electrolyte measurements.
Main Methods:
- Prospective cross-sectional study involving 48 dogs with hypoadrenocorticism.
- Paired blood samples analyzed on two POC analyzers and a reference laboratory.
- Statistical analysis using Bland-Altman and Passing-Bablok regression.
Main Results:
- Both POC analyzers demonstrated bias compared to the reference method.
- Poor agreement was observed for sodium and chloride concentrations.
- Analyzers generally reported higher electrolyte values than the reference method, except for VetStat's potassium readings.
Conclusions:
- Significant differences exist between POC analyzers and reference laboratory methods for electrolyte measurement in hypoadrenocorticism cases.
- Clinical relevance of these discrepancies warrants further investigation.
Related Concept Videos
Electrodes: Overview
2.4K
Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
2.4K
Diagnosing Acidosis and Alkalosis
889
Diagnosing acid-base imbalances involves systematically analyzing arterial blood samples, focusing on three key measurements: pH, bicarbonate (HCO3−) concentration, and carbon dioxide partial pressure (PCO2). This analysis follows a four-step process that helps identify the imbalance's underlying cause and nature.
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
889
Potentiometry: Types of Electrodes
1.7K
Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
1.7K
Electrogravimetric Analysis: Overview
627
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
To test the completeness of the...
627
Electrocardiogram
4.9K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
4.9K