Electrolyte measurements differ between point-of-care and reference analysers in dogs with hypoadrenocorticism
S Fowlie1, S Spence2, E Roberts3
1Small Animal Hospital, University of Glasgow, Glasgow, G61 1QH, UK.
Introduction:
Dogs treated for hypoadrenocorticism are monitored through analysis of their blood electrolytes. This is routinely performed with point-of-care analysers and doses of medications are adjusted based on the results.
Objectives:
To investigate the performance of two point-of-care analysers (IDEXX Catalyst Dx and IDEXX VetStat) against a reference laboratory method for the measurement of blood sodium, potassium and chloride concentrations, as well as sodium: potassium ratios, in dogs diagnosed with and treated for hypoadrenocorticism.
Methods:
Forty-eight dogs were enrolled into a prospective cross-sectional study. Paired blood samples were taken and tested on two point-of-care analysers and at a reference laboratory. Statistical analysis was then performed with Bland-Altman analysis and Passing-Bablok regression. The clinical effects of inaccurate electrolyte analysis were investigated.
Results:
In total, 329 samples were tested on the Catalyst analyser, while another 72 samples were tested on the VetStat. Passing-Bablok regression identified both proportional and constant bias for some analytes. There was poor agreement between sodium and chloride concentrations on both analysers. Both analysers tended to give higher results than the reference method for all analytes, except for potassium when measured on the VetStat.
Clinical Significance:
There are inherent differences between the electrolyte concentrations measured by these two point-of-care analysers and reference laboratory methods in dogs with hypoadrenocorticism.
Related Concept Videos
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Electrogravimetric Analysis: Overview
To test the completeness of the...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...