Fat-Water Phantoms for Magnetic Resonance Imaging Validation: A Flexible and Scalable Protocol
Published on: September 7, 2018
Semi-automatic magnetic resonance imaging based orbital fat volumetry: reliability and correlation with computed
R Willaert1, B Degrieck2, K Orhan3
1Department of Head and Neck Surgery, Ghent University Hospital, Ghent, Belgium; Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
Abstract:
Post-processing analysis can provide valuable information for diagnosis and planning of orbital disorders. This cross-sectional study aims to evaluate the reliability of semi-automatic, orbital fat volumetry using magnetic resonance imaging (MRI). Two observers assessed the orbital fat volume using a standard MRI protocol (3T, T1w sequence) in 12 orbits diagnosed with Graves' orbitopathy (GO) and 10 healthy control orbits. MRI and computed tomography (CT) based analysis were compared. Intra-observer variability was good (intraclass correlation coefficient (ICC) 0.88; 95% confidence interval (CI) [0.70, 0.95]) and interobserver agreement was moderate (ICC 0.55; 95% CI [-0.09, 0.81]), which corresponds to a mean percentage difference of 1.3% and 17.9% of the total orbital fat volume. Mean differences between MRI and CT measurements were, respectively, 1.1 cm3 (P= 0.064, 95% CI [-0.20, 2.43]) and 1.4 cm3 (P=0.016, 95% CI [0.21, 2.56]) for the control and the GO group. MRI volumetry was strongly correlated with CT (Pearson's r= 0.7, P<0.001). We conclude that orbital fat volumetry is feasible with a semi-automatic segmentation procedure and standard MRI protocol. Correlation with CT volumetry is good, but considerable bias may derive from observer variability and these errors should be taken into account for the purpose of volumetric analysis. Better definition of error sources may increase measurement accuracy.
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...