Stent evaluation by coronary computed tomography angiography: a comparison between Iopamidol-370 and Ioversol-320
Annelisa Moura Garcia1, Antonildes N Assunção-Jr1, Roberto Nery Dantas-Jr1
1Sirio-Libanes Hospital, Sao Paulo, SP, Brazil.
Objective:
Qualitative and quantitative image analysis between Iopamidol-370 and Ioversol-320 in stents´ evaluation by coronary computed tomography angiography (CTA).
Methods:
Sixty-five patients with low-risk stable angina undergoing stent follow-up with coronary CTA were assigned to Iopamidol I-370 (n = 33) or Ioversol I-320 (n = 32) in this prospective, double-blind, non-inferiority, randomized trial. Stent lumen image quality was graded by 5-point Likert Scale. Lumen mean attenuation was measured at native coronary segments: pre-stent, post-stent, distal segments and at coronary plaques. Lumen attenuation increase (LAI) ratio was calculated for all stents. Heart rate (HR) variation, premature heart beats (PHB), heat sensation (HS), blooming and beam hardening were also assessed.
Results:
Image quality was similar between groups, with no significant difference (Likert score 4.48 ± 0.75 vs 4.54 ± 0.65, p = 0.5). There were similarities in LAI ratio between I-370 and I-320 (0.39 ± 0.42 vs 0.48 ± 0.44 HU, p = 0.08). Regarding lumen mean attenuation at native coronary segments, a significant difference was observed, with I-320 presenting lower values, including contrast mean attenuation in distal segments. After statistical multivariate analysis, three variables correlated with stent image quality: 1) stent diameter, 2) HR variation and 3) stent lumen LAI ratio.
Conclusions:
There was no significant difference between Iopamidol-370 mgI ml-1 and Ioversol-320 mgI ml-1 contrasts regarding overall stent lumen image quality, which was mainly influenced by stent diameter, HR and LAI ratio.Advances in knowledge:Coronary CTA allows adequate stents' visualization and image quality is influenced by stent diameter, HR variation and LAI ratio.Stents' image quality showed no difference between different concentration contrasts (I-370 vs. I-320); however, higher concentration contrasts may provide an improved overall visualization, especially regarding coronary distal segments.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Redox Titration: Iodimetry and Iodometry
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Imaging Studies III: Computed Tomography