Related Experiment Video
Updated: Dec 11, 2025

Rodent Working Heart Model for the Study of Myocardial Performance and Oxygen Consumption
Published on: August 16, 2016
Quantification of left ventricular contribution to stroke work by longitudinal and radial force-length loops
Felicia Seemann1,2, Jonathan Berg1,3, Kristian Solem3
1Department of Clinical Sciences Lund, Clinical Physiology, Lund University, Skåne University Hospital, Lund, Sweden.
Abstract:
Left ventricular (LV) stroke work (SW) is calculated from the pressure-volume (PV) loop. PV loops do not contain information on longitudinal and radial pumping, leaving their contributions to SW unknown. A conceptual framework is proposed to derive the longitudinal and radial contributions to SW, using ventricular force-length loops reflecting longitudinal and radial pumping. The aim of this study was to develop and validate this framework experimentally and to explore these contributions in healthy controls and heart failure patients. Thirteen swine underwent cardiovascular magnetic resonance (CMR) and LV pressure catheterization at baseline (n = 7) or 1 wk after myocardial infarction (n = 6). CMR and noninvasive PV loop quantification were performed on 26 human controls and 14 patients. Longitudinal and radial forces were calculated as LV pressure multiplied by the myocardial surface areas in the respective directions. Length components were defined as the atrioventricular plane and epicardial displacements, respectively. Contributions to SW were calculated as the area within the respective force-length loop. Summation of longitudinal and radial SW had excellent agreement with PV loop-derived SW (ICC = 0.95, R = 0.96, bias ± SD = -4.5 ± 5.4%) in swine. Longitudinal and radial contributions to SW were ~50/50% in swine and human controls, and 44/56% in patients. Longitudinal pumping required less work than radial to deliver stroke volume in swine (6.8 ± 0.8 vs. 8.7 ± 1.2 mJ/mL, P = 0.0002) and in humans (11 ± 2.1 vs. 17 ± 4.7 mJ/mL, P < 0.0001). In conclusion, longitudinal and radial pumping contribute ~50/50% to SW in swine and human controls and 44/56% in heart failure patients. Longitudinal pumping is more energy efficient than radial pumping in delivering stroke volume.NEW & NOTEWORTHY A novel method for quantifying the contributions of longitudinal and radial pumping to stroke work using global left ventricular force-length loops was proposed and validated, which can be quantified noninvasively using cardiovascular magnetic resonance and brachial cuff pressure. We found that longitudinal and radial pumping contributes equally to stroke work in controls and 44/56% in heart failure patients, and that the longitudinal pumping is more energy efficient in delivering stroke volume than radial pumping.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...