Cone-Beam Computed Tomography Detection of Separated Endodontic Instruments
Flares Baratto-Filho1, Jéssica Vavassori de Freitas2, Flávia Sens Fagundes Tomazinho2
1Department of Dentistry, Universidade da Região de Joinville, Joinville, Santa Catarina, Brazil.
Journal of Endodontics
|August 21, 2020
Summary
Digital periapical radiography (DPR) is more accurate than cone-beam computed tomography (CBCT) for detecting separated endodontic instruments. However, neither imaging technique reliably identifies all fractured files in filled root canals.
Area of Science:
- Dentistry
- Endodontics
- Radiology
Background:
- Separated endodontic instruments pose a challenge in root canal treatment.
- Accurate identification of these fragments is crucial for successful treatment outcomes.
- Various imaging modalities are used, including cone-beam computed tomography (CBCT) and digital periapical radiography (DPR).
Purpose of the Study:
- To compare the diagnostic accuracy, sensitivity, and specificity of different CBCT protocols and DPR for identifying separated endodontic instruments in filled root canals.
- To evaluate the effectiveness of various imaging techniques in detecting fractured endodontic files.
Main Methods:
- 108 root canals in 36 mandibular molars were prepared and obturated, with 24 containing separated instruments (stainless steel hand files or reciprocating instruments).
- Images were acquired using three CBCT protocols (i-CAT Classic, i-CAT Next Generation, PreXion 3D) and one DPR protocol.
- Two endodontists assessed images for the presence of fractured files using a 5-point scale.
Main Results:
- Digital periapical radiography (DPR) identified 37.5% of separated instruments, while no instruments were detected with any CBCT protocol (P > .05).
- DPR demonstrated the highest accuracy (83.3%) and sensitivity (37.5%) among the tested methods.
- The type of separated instrument (stainless steel hand file or reciprocating instrument) did not significantly affect detection rates (P > .05).
Conclusions:
- Digital periapical radiography (DPR) is superior to the evaluated cone-beam computed tomography (CBCT) protocols (ICC, ICN, PXD) for detecting separated endodontic instruments.
- Despite DPR's higher accuracy, a significant number of separated instruments remained undetected by all imaging methods.
- Further research is needed to improve the detection rates of separated endodontic instruments.