Related Experiment Video
Updated: Dec 11, 2025

Assessment of Methane and Nitrous Oxide Fluxes from Paddy Field by Means of Static Closed Chambers Maintaining Plants Within Headspace
Published on: September 6, 2018
An investigation of a passive opened top-end pipe as an alternative solution for passive soil depressurisation
Le Chi Hung1, Jamie Goggins2, Patrick Meier2
1School of Physics, National University of Ireland Galway, Ireland; Civil Engineering, School of Engineering, National University of Ireland Galway, Ireland; MaREI Centre for Energy, Climate and Marine, Ryan Institute, National University of Ireland Galway, Ireland.
Abstract:
This study carried out a series of large-scale experimental tests and numerical simulations to investigate the performance of a passive opened top-end pipe as an alternative solution for passive soil depressurisation systems for indoor radon mitigation. Measurements were conducted in terms of wind velocity, extracted air velocity and negative pressure at the sump-end inside the pipe. Investigations were performed with controlled and natural wind conditions. Test results confirmed that the passive opened top-end pipe can be used as an alternative solution for indoor radon concentration mitigation at low additional construction cost. However, the extracted air velocity and negative pressure were found to fluctuate when tested under natural wind conditions. This fluctuation would reduce the effectiveness of the performance of the passive pipe. To reduce this fluctuation, a novel static ventilator has been developed and can be added on the top-end of the pipe.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
11:19Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
Related Concept Videos
Single Pipe Systems
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...