Related Experiment Video
Updated: Dec 11, 2025

Author Spotlight: Advancements in Intracardiac Echocardiography for Atrial Anatomy Assessment
Published on: June 30, 2023
Three-dimensional intracardiac echocardiography and pulmonary embolism
Konstantin Yastrebov1,2, Laurencie Brunel3,4, Hugh S Paterson3,4
1Sydney Core Research Facility, University of Sydney, Hybrid Theatre, Charles Perkins Building, Johns Hopkins Dr, Camperdown, Sydney, NSW, 2006, Australia. syastrebov@y7mail.com.
Background:
Three-dimensional intracardiac echocardiography (3D ICE) with wide azimuthal elevation is a novel technique performed for assessment of cardiac anatomy and guidance of intracardiac procedures, being able to provide unique views with good spatial and temporal resolution. Complications arising from this invasive procedure and the value of 3D ICE in the detection and diagnosis of acute cardiovascular pathology are not comprehensively described. This case illustrates a previously unreported iatrogenic complication of clot displacement from the intra-vascular sheath upon insertion of a 3D ICE catheter and the value of 3D ICE in immediate diagnosis of clot in transit through the heart with pulmonary embolism.
Case Presentation:
We conducted a translational study of 3D ICE with wide azimuthal elevation to guide implantation of a left ventricular assist device (Impella CP®) in eight adult sheep. A large-bore 14 Fr central venous sheath was used to enable right atrial and right ventricular access for the intracardiac catheter. Insertion of the 3D ICE catheter was accompanied by a sudden severe cardiorespiratory deterioration in one animal. 3D ICE revealed a large highly mobile mass within the right heart chambers, determined to be a clot-in-transit. The diagnosis of pulmonary clot embolism resulting from the retrograde blood entry into the large-bore sheath introducer, rapid clot formation and consequent displacement into venous circulation by the ICE catheter was made. The sheep survived this life-threatening event following institution of cardiovascular support allowing completion of the primary research protocol.
Conclusion:
This report serves as a serious warning to the researchers and clinicians utilizing long large-bore sheath introducers for 3D ICE and illustrates the value of 3D ICE in detecting clot-in-transit within right heart chambers.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Acute Coronary Syndrome III: Diagnostic Studies
Pulmonary Embolism I: Introduction
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...

