Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz
Vida Krikstolaityte1, Ruiyu Ding2, Tautgirdas Ruzgas3
1Nanyang Technological University, School Civil & Environmental Engineering, 50 Nanyang Avenue, Singapore, 639798, Singapore; Nanyang Technological University, Nanyang Environmental & Water Research Institute, R3C, 1 Cleantech Loop, Singapore, 637141, Singapore; Nanyang Technological University, Energy Research Institute @NTU (ERI@N), SCARCE laboratory, 50 Nanyang Avenue, Singapore, 639798, Singapore.
Abstract:
Nano-layered solid-contact potassium-selective electrodes (K+-ISEs) were explored as model ion-selective electrodes for their practical use in clinical analysis. The ultra-thin ISEs ought to be manufactured in a highly reproducible manner, potentially making them suitable for mass production. Thus, their development is pivotal towards miniaturised sensors with simplified conditioning/calibration protocols for point-of-care diagnostics. To study nano-layered ISEs, the ultra-thin nature of ISEs for the first time enabled to combine potentiometry-quartz crystal microbalance with dissipation (QCM-D) to obtain value-added information on the ISE potentiometric response regarding their physical state such as mass/thickness/viscoelastic properties/structural homogeneity. Specifically, the studies were focused on real-time observations of the ISE potentiometric response in relation to changes of their physicochemical properties during the ISE preparation (conditioning) and operation (including biofouling conditions) to identify the occurring processes that may accordingly be critical for potential instability of the ISEs, impeding their practical application. The K+-ISEs were prepared on a QCM-D gold sensor by electrodepositing poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate) layer serving as an ion-to-electron transducer subsequently covered by a spin-coated poly(vinyl chloride) based K+-ion selective membrane (K+-ISM). The studies demonstrated that the performance of the nano-layered design of K+-ISEs is detrimentally affected by such processes as water layer formation accordingly causing the instability of the electrode potential. The changes in the ISE physical state such mass/viscoelastic properties associated with water layer formation and origin of the potential instability was already observed at the ISE conditioning stage. The potential instability of nano-layered ISEs limits their practical applicability, indicating the need of new solutions in designing ISEs, for instance, exploiting new water-resistant materials and modifying preparation protocols.
Related Concept Videos
Potentiometry: Membrane Electrodes
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Overview
Electrogravimetric Analysis: Overview
To test the completeness of the...


