Related Experiment Video
Updated: Dec 11, 2025

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Electromagnetically-vibrated solid-phase microextraction for analysis of aqueous-miscible organic compound transport
Jin Chul Joo1, Charles D Shackelford2, Kenneth F Reardon3
1Associate Professor, Dept. of Civil and Environmental Engineering, Hanbat National Univ., Republic of Korea.
Abstract:
Current methods of sampling pore water from soil columns to determine solute concentrations are slow and require relatively large volumes. Accordingly, an electromagnetically-vibrated (EMV) solid-phase microextraction (SPME) device was evaluated for determining temporal and spatial distributions of solute pore-water concentrations (solute concentration profiles) for four organic compounds, two polar (2-hexanone, 2,4-dimethyl phenol) and two nonpolar (toluene, 1,4-dichlorobenzene), in columns packed with simulated aquifer sands with different fractions of organic carbon. In batch equilibrium extraction tests, the equilibrium extraction time of the organic compounds in aqueous mixtures decreased from 30 to less than 10 min as the frequency of electromagnetic vibration increased from zero to 250 Hz. Mixture effects were not statistically significant (p > 0.05) in the extraction process using EMV SPME. Comparisons of the solute concentration profiles within the soil columns at different elapsed times measured by pore-water samples and in situ EMV SPME extractions revealed both methods were equally effective. However, EMV SPME extraction removed no solution volume and only 0.6-14% of the solute mass removed by the pore-water sample collections, substantially minimizing disturbances to solute transport and fate. Thus, the equilibrium extraction-based calibration method using EMV SPME offers an effective approach for rapidly and accurately determining solute concentration profiles in column tests with negligible solute mass loss and minimal solution flow disturbance.
More Related Videos
13:16A Whole Cell Bioreporter Approach to Assess Transport and Bioavailability of Organic Contaminants in Water Unsaturated Systems
Published on: December 24, 2014
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Extraction: Advanced Methods
High-Performance Liquid Chromatography: Elution Process
Electrophoresis: Overview
There...
Ion-Exchange Chromatography
Analyte Adsorption and Distribution