Low-concentration hydrogen peroxide decontamination for Bacillus spore contamination in buildings
Ronald Leroy Mickelse1, Joseph Wood2, Michael Worth Calfee2
1U.S. Environmental Protection Agency, Office of Land and Emergency Management, Durham, North Carolina.
Abstract:
Remediation and recovery efforts after a release of Bacillus anthracis (anthrax) spores may be difficult and costly. In addition, response and recovery technologies may be focused on critical resources, leaving the small business or homeowner without remediation options. This study evaluates the efficacy of relatively low levels of hydrogen peroxide vapor (HPV) delivered from off-the-shelf equipment for the inactivation of Bacillus spores within an indoor environment. Decontamination evaluations were conducted in a house using both Bacillus atrophaeus var. globigii (Bg; as surrogates for B. anthracis ) inoculated on the carpet and galvanized metal as coupons and Geobacillus stearothermophilus (Gs) as biological indicators on steel. The total decontamination time ranged from 4 to 7 days. Using the longer exposure times, low concentrations of HPV (average levels below 20 parts per million) effectively inactivated Bg and Gs spores on the materials tested. The HPV was generated with commercial humidifiers and household-strength hydrogen peroxide solutions. The presence of home furnishings did not have a significant impact on HPV efficacy. This simple, inexpensive, and effective decontamination method could have significant utility for remediation following a B. anthracis spore release, such as following a terrorist attack.
More Related Videos
11:47Evaluation of the Efficacy of Organic Peroxyacids for Eradicating Dairy Biofilms Using an Approach Combining Static and Dynamic Methods
Published on: December 9, 2022
14:17The Portable Chemical Sterilizer PCS, D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Chemical Agents for Microbial Control
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Bioremediation
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...