Summary
Refractive errors like myopia, astigmatism, and presbyopia significantly impact binocular visual acuity during robotic surgery. Proper correction is crucial for surgeons to maintain optimal performance and patient safety in robotic procedures.
Area of Science:
- Ophthalmology
- Robotic Surgery
Background:
- Refractive errors are common and can affect visual performance.
- Robotic surgery requires high levels of visual acuity and precision.
Purpose of the Study:
- To evaluate the effect of refractive errors on binocular visual acuity during Da Vinci SI robotic system console use.
- To determine the impact of uncorrected refractive errors on surgical performance metrics.
Main Methods:
- Eighty volunteers used a near vision chart on the Da Vinci SI console.
- Refractive errors, anisometropia, and stereoacuity were measured.
- Binocular visual acuity (LogMAR) was assessed with and without correction (DiffLogMAR).
Main Results:
- Myopia/astigmatism significantly impacted DiffLogMAR (p < 0.001); myopia >1.75D showed higher DiffLogMAR (p < 0.05).
- Presbyopia significantly increased DiffLogMAR (p < 0.01) with a cutoff of 1.25D (p < 0.001).
- Hypermetropia correlated with DiffLogMAR (p < 0.01) and affected stereotactic view (p < 0.05).
Conclusions:
- Surgeons with myopia >1.75D, presbyopia >1.25D, or any hypermetropia need proper visual correction for robotic surgery.
- Undercorrected refractive errors can impair visual acuity and stereoacuity during robotic procedures.
- Ensuring adequate correction optimizes surgeon performance and patient safety in robotic-assisted surgery.