Related Experiment Video
Updated: Dec 11, 2025

Large-Scale SARS-CoV-2 Testing Utilizing Saliva and Transposition Sample Pooling
Published on: June 23, 2022
Diagnostic yield of repeat testing for SARS-CoV-2: Experience from a large health system in Los Angeles
Paul C Adamson1, David Goodman-Meza1, Tara Vijayan1
1Division of Infectious Diseases, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.
Objective:
To determine the diagnostic yield of repeat testing for SARS-CoV-2.
Methods:
A retrospective analysis was performed of all SARS-CoV-2 test results within the UCLA Health System between March 9th and April 29th, 2020. All patients with repeat test results were identified and those with discordant results were reviewed.
Results:
Between March 9th and April 29th there were 10,165 SARS-CoV-2 test results, of which 630 (6.2%) were positive. Among the 904 patients with repeat test results, 808 (89.4%) were initially negative and 96 (10.6%) were initially positive. Among the 808 patients with an initial negative test, 15 (1.9%) subsequently tested positive. Eleven cases with an initial negative SARS-CoV-2 test and without a known prior positive SARS-CoV-2 test were reviewed; 6 were employed as healthcare workers and 10 were positive on the second test.
Conclusions:
We found a low diagnostic yield of repeat testing for SARS-CoV-2 in our health system. Repeat testing might prove useful in certain clinical scenarios, such as in healthcare workers, when symptoms develop after a negative test, and in hospitalized patients with a high clinical suspicion for COVID-19.