Comparison of Omegawave Device and an Ambulatory ECG for RR Interval Measurement at rest
José Naranjo-Orellana1, José Francisco Ruso-Álvarez1, José Luis Rojo-Álvarez2
1Department of Sports and Computing, Pablo de Olavide University, Sevilla, Spain.
Abstract:
The aim of this study was to validate the measurements of the beat intervals taken at rest by the Omegawave® device by comparing them to an ambulatory electrocardiogram system. For this purpose, the electrocardiogram was digitally processed, time-aligned, and scrutinized for its suitable use as gold-standard. Rest measurements were made for 10 minutes on 5 different days to 10 men and 3 women (24.8±5.05 years; 71.82±11.02 kg; 174.35±9.13 cm). RR intervals were simultaneously recorded using the Omegawave device and a Holter electrocardiogram. The processing of Holter electrocardiogram signals included the detrending of baseline noise and a high-pass filtering for emphasizing the QRS complexes and attenuating the T waves. After obtaining the RR intervals from the electrocardiogram, those from the Omegawave device were automatically aligned to them with cross-correlation digital processing techniques and compared to check whether both measurements could be considered superimposable. A Bland-Altman analysis was applied to the 5 measurements made for all subjects. The Omegawave device exhibited very strong agreement with a quality-controlled Holter electrocardiogram. Deviations not exceeding 25 ms could be expected in 95% of the cases, which is within manageable ranges both for clinical practice and for sports.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation