Related Experiment Video
Updated: Dec 10, 2025

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Randomized Controlled Trial to Compare Baska® Mask versus ProSeal Laryngeal Mask Airway for General Anesthesia with
Balwinderjit Singh1, Arwinder Pal Singh1, Joginder Pal Attri2
1Department of Anesthesia, PIMS, Jalandhar, Punjab, India.
Introduction:
A myriad of supraglottic airway devices (SADs) are developed over time to search the device that conforms to the anatomy of the human respiratory tract noninvasively, but these devices are associated with the risk of aspiration. Baska® mask (BM) is the latest addition to the family of SADs to circumvent the incidence of aspiration.
Aims Of Study:
The aim of the study was to compare the sealing pressure and rapidity of the insertion of BM with ProSeal laryngeal mask (PLM) airway and the incidence of laryngopharyngeal morbidity between two devices.
Materials And Methods:
A randomized prospective open-label study was done on sixty adult patients of the age group of 18-60 years after approval from the institutional ethical committee and registration of trial in the Clinical Trials Registry. The patients were randomly divided into two groups: Group I (BM) where BM was inserted after the induction of general anesthesia and Group II (PLM) where PLM was inserted after induction. The airway sealing pressure in BM was calculated. The mean time of insertion of respective SAD and the number of successful attempts were also recorded in both groups. For analysis of continuous variables, independent sample Student's t-test was applied, and for categorical variables, Chi-square test was used. P < 0.05 was considered statistically significant.
Results:
The rate of successful attempts of insertion was comparable in both the groups. The mean insertion time was 14.25 ± 3.82 s in BM group and 22.01 ± 2.64 s in PLM group, which was statistically significant. The airway sealing pressure was 30.25 ± 3.34 cmH2O in BM group and 23.50 ± 4.05 cmH2O in PLM group, which was also statistically significant.
Conclusion:
BM has better ease of insertion with adequate sealing pressure as compared to PLM airway, thus reducing the chances of aspiration and offering its potential application in securing airway in emergency situations.
More Related Videos
05:39Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
05:43Topical Airway Anesthesia for Awake-endoscopic Intubation Using the Spray-as-you-go Technique with High Oxygen Flow
Published on: January 13, 2017
Related Concept Videos
Cardiopulmonary Resuscitation II: ACLS Airway Management
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Stages of General Anesthesia
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...