Related Experiment Video
Updated: Dec 10, 2025

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
Overuse of brain CT scan for evaluating mild head trauma in adults
Farzaneh Shobeirian1, Zahra Ghomi2, Reza Soleimani3
1Department of Radiology, Razi Hospital, Guilan University of Medical Sciences, Rasht, Iran.
Introduction:
CT scan is crucial in evaluating head trauma. However, its inappropriate use will cause unnecessary radiation exposure to patient and financial burden to health systems. Our aim is appraising amount of brain CT scans performed in our Emergency Department (ED) for evaluating mild head trauma which are not indicated according to four standardized guidelines as well as analyzing contributing factors.
Methods:
This was a descriptive prospective study. We included randomly selected adult patients under 75 years old with minor head trauma evaluated by brain CT scan at our ED. For all patients, we completed a checklist including demographic data, mechanism of trauma, specialty of the requesting physician, and whether the patient meets the brain CT guidelines criteria. Brain CT overuse was defined as scans performed for patients without criteria of any of the standardized guidelines.
Results:
We evaluated 170 patients. The mean age of patients was 38.38 ± 19.73 years old. The most common mechanism of trauma was falling (37.6%). The overall brain CT scan overuse was 15.3%. Most of the overused scans were performed in younger patients, and patient's age was inversely correlated to overuse. There was no significant difference based on the mechanism of trauma and the specialty of requesting physician.
Discussion:
Our study accentuates the high frequency of brain CT scan overuse, leading to unnecessary radiation exposure and financial burden on healthcare systems. We emphasize that using a guideline for requesting brain CT scan can eliminate unnecessary scans along with detecting patients with important decisive damages.
More Related Videos
08:27Development of an Uncomplicated Mild Traumatic Brain Injury Model Modified by Weight-Drop Method and Evidenced by Magnetic Resonance Imaging
Published on: April 11, 2025
10:33Advanced Diffusion Imaging in The Hippocampus of Rats with Mild Traumatic Brain Injury
Published on: August 14, 2019
Related Concept Videos
Brain Imaging
These technologies include computerized axial tomography (CAT or CT scans), positron-emission tomography (PET scans), magnetic resonance imaging (MRI), functional magnetic resonance imaging (fMRI), and Transcranial Magnetic...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...