Related Experiment Video
Updated: Dec 10, 2025

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Reliability of alternative devices for postoperative patient temperature measurement: two prospective, observational
V M Aykanat1, E Broadbent2, P J Peyton1
1Department of Anaesthesia, Austin Hospital, Melbourne, Victoria, Australia.
Abstract:
Peri-operative hypothermia is associated with significant morbidity, yet limitations exist regarding non-invasive temperature assessment in the post-anaesthesia care unit (PACU). In this prospective study of 100 patients, we aimed to determine the reliability of two commonly used temperature measurement devices, forehead temporal artery temperature and tympanic measurement, in addition to an indwelling urinary catheter with temperature probe, in comparison with the final nasopharyngeal core temperature at the end of surgery. Agreement of forehead measurement with nasopharyngeal temperature showed a mean bias (±95% limits of agreement) of 0.15 °C (±1.4 °C), with a steep slope of the relationship on the Bland-Altman plot of -0.8, indicating a tendency to normalise patient temperature readings to 36.4 °C. Only 54% of hypothermic cases were correctly detected by the forehead measurement device. Agreement of tympanic measurement with nasopharyngeal core temperature measurement was marginally improved with a mean bias of 0.13 °C (95% limits of agreement ±1.15 °C). In contrast, agreement of bladder temperature with nasopharyngeal temperature showed a mean (SD) bias of 0.19 (0.28) °C (95% limits of agreement ±0.54 °C), with a relatively flat line of best fit. We demonstrated that two commonly used temperature measurement devices, forehead temporal artery temperature and tympanic measurement, compared with nasopharyngeal core temperature, were imprecise and unreliable following major surgery. However, the indwelling catheter with temperature sensor was precise and acceptable for continuous core temperature measurement in the PACU.
More Related Videos
04:34Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
05:43Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...