Related Experiment Video
Updated: Dec 10, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Does dose optimisation in digital panoramic radiography affect diagnostic performance?
Luciano Augusto Cano Martins1, Danieli M Brasil2, Laís A Forner3
1Department of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901-Areião, Piracicaba, SP, Brazil. luciano_cano@hotmail.com.
Objectives:
To compare the overall diagnostic performance of digital panoramic radiographs obtained with low-dose protocols and to estimate the absorbed dose in the head and neck.
Materials And Methods:
Forty-eight panoramic radiographs were obtained from eight imaging phantoms using six exposure protocols of progressively lower tube voltages (kVp) and currents (mA), as follows: (1) 70 kVp and 12.5 mA, (2) 66 kVp and 10 mA, (3) 66 kVp and 8 mA, (4) 66 kVp and 5 mA, (5) 66 kVp and 4 mA and (6) 66 kVp and 3.2 mA. Five oral radiologists independently evaluated the images and reported all detectable radiographic findings. Intra-examiner reproducibility was assessed by re-evaluation of 25% of the images. The data were analysed using the McNemar and weighted Kappa tests. Absorbed doses of the six protocols were obtained from thermoluminescent dosimeters placed inside a Rando phantom and compared using one-way ANOVA with post hoc Tukey (α = 0.05).
Results:
The overall diagnostic performance of panoramic radiographs obtained with low-dose protocols did not differ from that of panoramic radiographs obtained with the highest dose (p > 0.05). Moreover, substantial agreement was observed between all protocols. Protocol 1 resulted in the highest absorbed dose and protocols 4, 5 and 6 in the lowest absorbed doses, with the difference being significant (p ≤ 0.05).
Conclusion:
Although digital panoramic radiography is considered a relatively low-dose examination, the radiation dose can be further reduced without negatively affecting its overall diagnostic performance.
Clinical Relevance:
Considering the risks associated with X-rays, digital panoramic radiographs can be obtained at even lower exposure levels.
More Related Videos
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...