Comparability of compressed sensing-based gradient echo perfusion sequence SPARSE and conventional gradient echo
Fabian Muehlberg1, Arthur Stoetzner1, Christoph Forman2
1HELIOS Hospital Berlin-Buch, Department of Cardiology and Nephrology, Lindenberger Weg 80, 13125 Berlin, Germany.
Purpose:
Stress perfusion imaging plays a major role in non-invasive detection of coronary artery disease. We compared a compressed sensing-based and a conventional gradient echo perfusion sequence with regard to image quality and diagnostic performance.
Method:
Patients sent for coronary angiography due to pathologic stress perfusion CMR were recruited. All patients underwent two adenosine stress CMR using conventional TurboFLASH and prototype SPARSE sequence as well as quantitative coronary angiography with fractional flow reserve (FFR) within 6 weeks. Coronary angiography was considered gold standard with FFR < 0.75 or visual stenosis >90 % for identification of myocardial ischemia. Diagnostic performance of perfusion imaging was assessed in basal, mid-ventricular and apical slices by quantification of myocardial perfusion reserve (MPR) analysis utilizing the signal upslope method and a deconvolution technique using the fermi function model.
Results:
23 patients with mean age of 69.6 ± 8.9 years were enrolled. 46 % were female. Image quality was similar in conventional TurboFLASH sequence and SPARSE sequence (2.9 ± 0.5 vs 3.1 ± 0.7, p = 0,06). SPARSE sequence showed higher contrast-to-noise ratio (52.1 ± 27.4 vs 40.5 ± 17.6, p < 0.01) and signal-to-noise ratio (15.6 ± 6.2 vs 13.2 ± 4.2, p < 0.01) than TurboFLASH sequence. Dark-rim artifacts occurred less often with SPARSE (9 % of segments) than with TurboFLASH (23 %). In visual assessment of perfusion defects, SPARSE sequence detected less false-positive perfusion defects (n = 1) than TurboFLASH sequence (n = 3). Quantitative perfusion analysis on segment basis showed equal detection of perfusion defects for TurboFLASH and SPARSE with both upslope MPR analysis (TurboFLASH 0.88 ± 0.18; SPARSE 0.77 ± 0.26; p = 0.06) and fermi function model (TurboFLASH 0.85 ± 0.24; SPARSE 0.76 ± 0.30; p = 0.13).
Conclusions:
Compressed sensing perfusion imaging using SPARSE sequence allows reliable detection of myocardial ischemia.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
06:29Cardiac Magnetic Resonance for the Evaluation of Suspected Cardiac Thrombus: Conventional and Emerging Techniques
Published on: June 11, 2019
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Imaging Studies for Cardiovascular System V: CT
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Acute Coronary Syndrome III: Diagnostic Studies