Related Experiment Video
Updated: Dec 10, 2025

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Artificial Intelligence Trumps TAVI2-SCORE and CoreValve Score in Predicting 1-Year Mortality Post-Transcatheter
Pradyumna Agasthi1, Hasan Ashraf1, Sai Harika Pujari1
1Department of Cardiovascular Diseases, Mayo Clinic Arizona, Phoenix, AZ, United States of America.
Background/Purpose:
Machine learning has been used to predict procedural risk in patients undergoing various medical interventions and procedures. One-year mortality in patients after Transcatheter Aortic Valve Replacement (TAVR) has a wide range (from 8.5 to 24% in various studies). We sought to apply machine learning to determine predictors of one year mortality in patients undergoing TAVR.
Methods/Materials:
A retrospective study of 1055 patients who underwent TAVR (Jan 2014-June 2017) with one-year follow up was completed. Baseline demographics, clinical, electrocardiography (ECG), Computed Tomography (CT) and echocardiography data were abstracted. Variables with near zero variance or ≥50% missing data were excluded. The Gradient Boosting Machine learning (GBM) prediction model included 163 variables and was optimized using 5-fold cross-validation repeated 10-times. The receiver operator characteristic (ROC) for the GBM model was calculated to predict one-year mortality post TAVR, and then compared to the TAVI2-SCORE and CoreValve score.
Results:
Among 1055 TAVR patients (mean age 80.9 ± 7.9 years, 42% female), 14.02% died at one year. 78% had balloon expandable valves placed. Based on GBM, the ten most predictive variables for one-year survival were cardiac power index, hemoglobin, systolic blood pressure, INR, diastolic blood pressure, body mass index, valve calcium score, serum creatinine, aortic annulus area, and albumin. The area under ROC to predict survival for the GBM model vs TAVI2-SCORE and CoreValve Score was 0.72 (95% CI 0.68-0.78) vs 0.56 (95%CI 0.51-0.62) and 0.53 (95% CI 0.47-0.59) respectively with p < 0.0001.
Conclusion:
The GBM model outperforms TAVI2-SCORE and CoreValve Score in predicting mortality one-year post TAVR.
Related Concept Videos
Aortic Regurgitation III: Medical Management
Mitral Valve Prolapse II: Assessment and Management
Aortic Regurgitation II: Clinical Features and Diagnostic Tests
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Aortic Regurgitation I: Introduction
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...