Related Experiment Video
Updated: Dec 10, 2025

Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Automated closed-loop versus standard manual oxygen administration after major abdominal or thoracic surgery: an
Erwan L'Her1,2, Samir Jaber3, Daniel Verzilli3
1Medical Intensive Care, CHRU de Brest - La Cavale Blanche, Brest, France.
Introduction:
Hypoxaemia and hyperoxaemia may occur after surgery, with related complications. This multicentre randomised trial evaluated the impact of automated closed-loop oxygen administration after high-risk abdominal or thoracic surgeries in terms of optimising the oxygen saturation measured by pulse oximetry time within target range.
Methods:
After extubation, patients with an intermediate to high risk of post-operative pulmonary complications were randomised to "standard" or "automated" closed-loop oxygen administration. The primary outcome was the percentage of time within the oxygenation range, during a 3-day frame. The secondary outcomes were the time with hypoxaemia and hyperoxaemia under oxygen.
Results:
Among the 200 patients, time within range was higher in the automated group, both initially (≤3 h; 91.4±13.7% versus 40.2±35.1% of time, difference +51.0% (95% CI -42.8-59.2%); p<0.0001) and during the 3-day period (94.0±11.3% versus 62.1±23.3% of time, difference +31.9% (95% CI 26.3-37.4%); p<0.0001). Periods of hypoxaemia were reduced in the automated group (≤3 days; 32.6±57.8 min (1.2±1.9%) versus 370.5±594.3 min (5.0±11.2%), difference -10.2% (95% CI -13.9--6.6%); p<0.0001), as well as hyperoxaemia under oxygen (≤3 days; 5.1±10.9 min (4.8±11.2%) versus 177.9±277.2 min (27.0±23.8%), difference -22.0% (95% CI -27.6--16.4%); p<0.0001). Kaplan-Meier analysis depicted a significant difference in terms of hypoxaemia (p=0.01) and severe hypoxaemia (p=0.0003) occurrence between groups in favour of the automated group. 25 patients experienced hypoxaemia for >10% of the entire monitoring time during the 3 days within the standard group, as compared to the automated group (p<0.0001).
Conclusion:
Automated closed-loop oxygen administration promotes greater time within the oxygenation target, as compared to standard manual administration, thus reducing the occurrence of hypoxaemia and hyperoxaemia.
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Endoscopic Studies II: Thoracocentesis
Description