Measurement and Control of an Incubator Temperature by Using Conventional Methods and Fiber Bragg Grating (FBG) Based
Mustafa Burunkaya1, Murat Yucel2
1Faculty of Technology, Department of Electrical and Electronics Engineering, Gazi University, 06500, Ankara, Turkey. bmustafa@gazi.edu.tr.
Abstract:
Incubator is a medical device that provide a climatic environment for a newborn and a preterm infant. In the incubator environment, especially, the temperature significantly increases the survival rate of infants. In this study, the incubator air temperature, temperature uniformity and infant skin temperature were measured and controlled with conventional methods and FBG based temperature sensors, and their results and related literature results were compared among them. To this end, in addition to classical sensors, six FBG sensors were used during the measurements, and very close results were obtained between them (R2 = 0.9989). In addition, since real time monitoring of the FBG bands were ensured with a user-friendly interface, measurement processes have been made more ergonomic. In this way, the insulation required for the measurements is also provided perfectly. Measurement errors caused by conventional sensors' properties, which are different for each of them, change over/with time, and also change with different values, have been minimized by using this method. Moreover, in case of increasing the number of sensors for multi-point, continuous and real time temperature measurement in conventional methods, some of the problems such as monitoring of these sensors, obstructing or changing the air flow due to the confusions of these sensors and their cables in the incubator cabinet, and following these, control errors caused by these reasons, and difficulties that may be happened during the infant care and resuscitation procedures have been eliminated. Thus, thermoneutrality in closed incubators were also able to validated and assessed fast and more accurately for preterm and neonates.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Physical Methods for Controlling Microbial Growth: Temperature
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Microbial Growth Measurement: Indirect Methods
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...