Reliability of Sonography-based Volume Computer Aided Diagnosis in the Normal Fetal Heart
Wan Yu Hu1, Yan Cheng Yu2, Li Ya Dai3
1Department of Diagnostic Ultrasound & Echocardiography, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, People's Republic of China.
Objectives:
To explore the inter- and intra-observer reliability of Sonography-based Volume Computer Aided Diagnosis (SonoVCAD) in the display of 8 diagnostic planes of fetal echocardiography and to evaluate its efficiency.
Methods:
Three-dimensional volume data sets of the 56 normal singleton fetuses were acquired from a 4-chamber view by using a volume probe. After processing the data sets by using SonoVCAD, 8 cardiac diagnostic planes were displayed automatically. Three doctors with different experiences of performing fetal echocardiography evaluated each diagnostic plane and the success rates of 8 diagnostic planes were calculated. Inter-observer and intra-observer reliabilities were estimated by Cohen's kappa statistics.
Results:
A total of 276 volume data sets acquired from the 56 normal fetuses were used for SonoVCAD analysis and display. The success rate of each diagnostic section was more than 90%, ranging from 90.6% to 99.6%. Among 276 volumes, 81.5% (225/276) of volumes were able to generate all 8 diagnostic views successfully. Moderate to substantial agreement (kappa, 0.509-0.794) was found between 2 less experienced operators. Moderate to near-perfect agreement (kappa, 0.439-0.933) was found between an expert and 2 less experienced sonographers. Intra-observer reliability was substantial to near-perfect (kappa, 0.602-0.903). The efficiency of SonoVCAD was assessed. The expert spent less time than 2 less experienced examiners (P < 0.001) but no significant difference was found between 2 less experienced examiners (P = 0.176). Besides, SonoVCAD consumed significantly less time than 2-dimensional ultrasound (P < 0.001).
Conclusions:
SonoVCAD can significantly improve the success rates of 8 diagnostic planes in fetal echocardiography with low operator dependency, good reproducibility and high efficiency.
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...