Photonic Voltage Transducer with Lightning Impulse Protection for Distributed Monitoring of MV Networks

Grzegorz Fusiek1, Pawel Niewczas1

  • 1Department of Electronic and Electrical Engineering, University of Strathclyde, Glasgow G1 1XW, UK.

Related Concept Videos

Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
351
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
466
Series R—L Circuit Transients01:22

Series R—L Circuit Transients

In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
294
Three-Phase Voltages01:30

Three-Phase Voltages

A three-phase generator produces three voltages that are equal in magnitude but have a phase difference of 120 degrees. This identical magnitude and equal phase separated voltages are known as the balanced voltages and help to minimize power loss while ensuring a steady delivery of energy to connected loads. As voltage sources in a three-phase system can be configured in a wye or a delta formation, the loads connected to these systems can also be arranged in either configuration. This...
455
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
435
Induced Electric Fields: Applications01:27

Induced Electric Fields: Applications

An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
2.3K