Metallic implants and CT artefacts in the CTV area: Where are we in 2020?
A Rousselle1, A Amelot2, J Thariat3
1Department of Radiation Oncology, Sorbonne Université, AP-HP, hôpitaux universitaires La Pitié Salpêtrière-Charles-Foix, 75013 Paris, France.
Abstract:
Radiation therapy (RT) is one of the main modalities of cancer treatment worldwide with computed tomography (CT), as the most commonly used imaging method for treatment planning system (TPS). Image reconstruction errors may greatly affect all the radiation therapy planning process, such as target delineation, dose calculation and delivery, particularly with particle therapy. Metallic implants, such as hip and spinal implants, and dental filling significantly deteriorate image quality. These hardware structures are often very complex in geometry leading to geometric complex artefacts in the clinical target volume (CTV) area, rendering the delineation of CTV challenging. In our review, we focus on the methods to overcome artefact consequences on CTV delineation: 1- medical approaches anticipating issues associated with imaging artefacts during preoperative multidisciplinary discussions while following standard recommendations; 2- common metal artefact reduction (MAR) methods such as manually override artefact regions, ballistics avoiding beam paths through implanted materials, megavoltage-CT (MVCT); 3- prospects with radiolucent implants, MAR algorithms and various methods of dual energy computed tomography (DECT). Despite substantial and broad evidence for their benefits, there is still no universal solution for cases involving implanted metallic devices. There is still a high need for research efforts to adapt technologies to our issue: "how do I accurately delineate the ideal CTV in a metal artefact area?"
More Related Videos
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT