Related Experiment Video
Updated: Dec 10, 2025

Using Magnetometry to Monitor Cellular Incorporation and Subsequent Biodegradation of Chemically Synthetized Iron Oxide Nanoparticles
Published on: February 27, 2021
Single cell magnetometry by magnetophoresis vs. bulk cell suspension magnetometry by SQUID-MPMS - a comparison
Wei Xue1,2, Lee R Moore1, Naruhiko Nakano3
1Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, 9500 Euclid Avenue, OH 44195, United States.
Abstract:
Paramagnetic constituents of a cell have strong effect on cell's volume magnetic susceptibility even at low volume fraction because of their high susceptibility relative to that of the diamagnetic cell constituents. The effect can be measured at a single cell level by measuring cell terminal velocity in viscous media using a microscope equipped with a well-defined field and gradient magnet configuration (referred to as magnetophoretic analysis by cell tracking velocimetry, CTV). The sensitivity of such a microscopic-scale magnetometry was compared to that of a reference method of superconducting quantum interference-magnetic properties measurement system (SQUID-MPMS) using a red blood cell (RBC) suspension model. The RBC hemoglobin oxygen saturation determines the hemoglobin molecular magnetic susceptibility (diamagnetic when fully oxygenated, paramagnetic when fully deoxygenated or converted to methemoglobin). The SQUID-MPMS measurements were performed on an average of 5,000 RBCs in 20 μL physiological phosphate buffer at room temperature, those by CTV on a single cell track in a mean magnetic field of 1.6 T and mean gradient of 240 T/m, repeated for an average of 1,000 tracks per sample. This suggests 5,000× higher sensitivity of cell susceptometry by magnetophoretic analysis than by SQUID-MPMS. The magnetophoretic mean RBC magnetic susceptibilities were in the range determined by SQUID-MPMS (lower limit) and theory (upper limit). The ability of magnetophoretic analysis to resolve susceptibility peaks in a mixed cell populations was confirmed for an oxy RBC and met RBC mixture. Magnetophoretic analysis by CTV provides new tool for studies of emergence of paramagnetic reaction products in the cell.
More Related Videos
07:55Integrated Cell Manipulation Platform Coupled with the Single-probe for Mass Spectrometry Analysis of Drugs and Metabolites in Single Suspension Cells
Published on: June 21, 2019
09:54Fabrication of Magnetic Platforms for Micron-Scale Organization of Interconnected Neurons
Published on: July 14, 2021