Objective:
To determine sound levels resulting from aural suctioning of the external auditory canal.
Methods:
Unweighted decibels (dB) and A-weighted decibels (dBA) sound pressure level measurements were recorded using a retrotympanic microphone in cadaveric human temporal bones. Sound measurements were made with common otologic suctions, size 3, 5, and 7 French, within the external ear canal at the tympanic membrane, 5, and 10 mm from the tympanic membrane in the dry condition. In the wet condition, the ear canal was filled with fluid and completely suctioned clear to determine sound effects of suctioning liquid from the ear canal.
Results:
Sound levels generated from ear canal suctioning ranged from 68.3 to 97 dB and 62.6 to 95.1 dBA. Otologic suctions positioned closer to the tympanic membrane resulted in louder sound levels, but was not statistically significant (P > .05). Using larger diameter suctions generated louder dB and dBA sound levels (P < .001) and the addition of liquid in the ear canal during the suction process generated louder dB and dBA sound levels (P < .001).
Conclusions:
Smaller caliber suction sizes and nonsuctioning techniques should be utilized for in-office aural toilet to reduce noise trauma and patient discomfort.
Level Of Evidence:
5.
More Related Videos
07:06Endaural Endoscopic Atticoantrotomy Retrograde Mastoidectomy using a Constant Suction Bone-drilling Technique
Published on: May 23, 2021
09:18A Comparative Study of Drug Delivery Methods Targeted to the Mouse Inner Ear: Bullostomy Versus Transtympanic Injection
Published on: March 8, 2017
Related Concept Videos
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Suctioning the Nasopharyngeal Airway
Equipment Required
Anatomy of the Ear
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Tracheostomy Suctioning II: Procedure
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...