Summary
The masking-level difference (MLD) decreases with masker level. An internal noise explanation, where partially uncorrelated internal noise decorrelates maskers at low levels, fits decades of MLD data.
Area of Science:
- Auditory perception
- Psychoacoustics
- Hearing science
Background:
- Masking-level difference (MLD) research often measures MLD as a function of masker level.
- Previous findings indicate MLD size decreases as masker level decreases.
- The role of additive internal noise in this masker level dependency has been under-examined.
Purpose of the Study:
- To review and evaluate the additive internal noise explanation for the masker level dependency of the MLD.
- To assess the fit of this explanation to historical and recent MLD data.
- To compare MLD behavior with insert versus supraaural earphones in light of internal noise.
Main Methods:
- Review of existing literature and data on masking-level difference (MLD) as a function of masker level.
- Analysis of how additive internal noise, particularly its interaural decorrelation at low masker levels, influences MLD.
- Comparison of MLD masker level functions obtained with insert phones versus supraaural phones.
Main Results:
- The additive internal noise explanation provides a robust fit to MLD data spanning four decades.
- This explanation accounts for the observed decrease in MLD size as masker level decreases.
- MLD shows less dependence on masker level with insert phones, consistent with lower internal noise.
Conclusions:
- The additive internal noise model effectively explains the masker level dependency of the MLD.
- Lower internal noise levels associated with insert earphones lead to reduced MLD masker level effects.
- The internal noise explanation should be a key consideration in studies measuring MLD as a function of masker level.