Quantitative contrast-enhanced ultrasound of the brain on twin fetal lambs maintained by the extrauterine environment for neonatal development (EXTEND): initial experience
Related Experiment Video
Updated: Dec 10, 2025

Contrast Imaging in Mouse Embryos Using High-frequency Ultrasound
Published on: March 4, 2015
Anush Sridharan1, Kendall M Lawrence2, Juan S Martin-Saavedra1
1Department of Radiology, The Children's Hospital of Philadelphia, 3401 Civic Center Blvd., Philadelphia, PA, 19104, USA.
Background:
With the development of an artificial environment to support the extremely premature infant, advanced imaging techniques tested in this extrauterine system might be beneficial to evaluate the fetal brain.
Objective:
We evaluated the feasibility of (a) performing contrast-enhanced ultrasound (CEUS) and (b) quantifying normal and decreased brain perfusion in fetal lambs maintained on the extrauterine environment for neonatal development (EXTEND) system.
Materials And Methods:
Twin premature fetal lambs (102 days of gestational age) were transferred to the EXTEND system. Twin B was subjected to sub-physiological flows (152 mL/kg/min) and oxygen delivery (15.9 mL/kg/min), while Twin A was maintained at physiological levels. We administered Lumason contrast agent into the oxygenator circuit and performed serial CEUS examinations. We quantified perfusion parameters and generated parametric maps. We also recorded hemodynamic parameters, serum blood analysis, and measurements across the oxygenator. Postmortem MRIs were performed.
Results:
No significant changes in hemodynamic variables were attributable to CEUS examinations. On gray-scale images, Twin B demonstrated ventriculomegaly and progressive parenchymal volume loss culminating in hydranencephaly. By CEUS, Twin B demonstrated decreased peak enhancement and decreased overall parenchymal perfusion when compared to Twin A by perfusion parameters and parametric maps. Changes in perfusion parameters were detected immediately following blood transfusion. Postmortem MRI confirmed ultrasonographic findings in Twin B.
Conclusion:
In this preliminary experience, we show that CEUS of the brain is feasible in fetal lambs maintained on the EXTEND system and that changes in perfusion can be quantified, which is promising for the application of CEUS in this extrauterine system supporting the premature infant.