Armed with the Facts: A Method for the Analysis of Smokeless Powders by Ambient Mass Spectrometry
Related Experiment Video
Updated: Dec 10, 2025

Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
Callum Bonnar1, Rachel Popelka-Filcoff1,2, K Paul Kirkbride1
1College of Science and Engineering, Flinders University, Bedford Park, South Australia 5042, Australia.
Abstract:
The work presented here follows several others in investigating what capabilities, if any, ambient mass spectrometry might have toward the analysis of compounds commonly associated with smokeless propellant powders. This family of instrumental techniques has attracted curiosity from the field of forensic science due to its desirable properties such as rapid collection of information-rich data, combined with minimal requirements for sample mass and preparation. Experiments were conducted with a "Direct Sample Analysis" ion source integrated with a time-of-flight mass spectrometer. The ionization behaviors of nitroglycerin, methyl and ethyl centralite, akardite, diphenylamine, nitrosodiphenylamine, and nitrated diphenylamine derivatives were investigated specifically, with accurate-mass data presented for each. Diphenylamine standards were used to demonstrate the performance of this instrument, which exhibited good response linearity across 1 order of magnitude and sub-nanogram detection limits. Thirty smokeless powder extracts, recovered from ammunition potentially in circulation within Australia, were analyzed to determine whether the technique is appropriate for rapid analysis of smokeless powder particles. Results demonstrated that the technique might be applied to compare individual particles with each other or to a database. Such a capability may be of value in the examination of explosive devices containing smokeless powder, postblast residues therefrom, or muzzle discharge from a close-range shooting. However, when efforts were made to detect residues from the hands of a volunteer shooter, only some returned positive results, and a high background signal from the sample collection stub indicates that detection using this instrument is thus far insufficiently reliable.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer SMPS-ICPMS
Published on: July 11, 2017
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Flame Photometry: Overview
Mass Spectrometers