Background:
The intubation of patients with coronavirus disease 2019 (COVID-19) puts health care workers at risk of infection through aerosol, droplet and contact contamination. We evaluated the risk of droplet and contact contamination for health care workers using 3 intubation barrier techniques as part of a quality assurance study at our institution.
Methods:
This randomized quality assurance study was completed at a tertiary academic hospital in Vancouver, British Columbia, Canada, on Apr. 4, 2020. Participants in personal protective equipment performed simulated intubations on a manikin with (a) no barrier, (b) a clear plastic sheet covering the manikin and (c) a plexiglass intubation box over the manikin, in random order. Fluorescein was ejected from inside the manikin's mouth to simulate droplet and contact spread during a standard intubation sequence. Two blinded independent assessors evaluated the location and degree of contamination on the intubator and assistant using an ultraviolet light. Contamination severity was rated in a standard fashion (0 = none; 1 = minor; 2 = major). The primary outcome was total contamination score and secondary outcomes were scores between intubator and assistant, anatomic areas contaminated and qualitative feedback on ease of intubation.
Results:
Five participants completed this study. Total contamination score was different between the 3 groups for the intubator (p = 0.02) but not the assistant (p = 0.2). For the intubator, the total contamination score was higher when the sheet was used (median 29 [interquartile range (IQR) 25-34]) than when the box was used (median 17 [IQR 15-22]) or when no barrier was used (median 18 [IQR 13-21]). All 5 participants reported challenges during intubation using the sheet.
Interpretation:
Use of a plastic sheet while intubating patients with COVID-19 may increase the risk of droplet and contact contamination during intubation and impede intubation. Further study should be undertaken before implementing barrier techniques in practice.
More Related Videos
Related Concept Videos
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Key Techniques in Microbiology