Improved Efficacy of Topical Latanoprost 0.005% Demonstrated by Corneal Biomechanical Correcting Modified Goldmann Prism
Related Experiment Video
Updated: Dec 10, 2025

Glaucoma-inducing Procedure in an In Vivo Rat Model and Whole-mount Retina Preparation
Published on: March 12, 2016
Nathan Radcliffe1, John Berdahl2, Mitchel Ibach2
1New York Eye Surgery Center, New York, NY, USA.
Purpose:
To evaluate intraocular pressure (IOP) reduction measured by a Goldmann applanation tonometer (GAT) prism and a modified surface Goldmann (CATS) prism with the institution of a topical prostaglandin analog (PGA) or alternatively a topical beta blocker.
Design:
Prospective, open-label, randomized, controlled, and reference device comparison.
Methods:
Thirty-six (36) treatment naïve glaucoma patients (72 eyes) were randomized equally to treatment with latanoprost 0.005% or timolol maleate 0.5%. Each patient underwent IOP measurement with standard GAT and CATS prisms before and at 1, 3, and 6 months of treatment. Central corneal thickness (CCT) and corneal hysteresis (CH) were also measured. Medication response was defined as a 20% reduction in IOP from baseline.
Results:
The CATS prism demonstrated the IOP reduction with topical latanoprost at a mean of 1.9 mmHg lower than the IOP measured with GAT (p=0.01). The CATS and GAT prisms detected no difference in IOP reduction with timolol (p=0.23). The number of latanoprost treatment non-responders was reduced from 36.1% measured with GAT to 13.8% when measured with the CATS prism (p=0.005). Timolol indicated no difference in the treatment non-response rate at 22.2% (p=0.999). CH increased significantly with latanoprost treatment by an average of 0.55 mmHg (p=0.014) and remained unchanged with timolol at -0.014 mmHg (p=0.68).
Discussion:
IOP reduction and responder rates were increased when measured with a CATS prism in patients using latanoprost and not with timolol use. Latanoprost-induced alterations in corneal biomechanics may dampen the actual IOP reduction measured with a standard GAT prism.
Clinical Trial Registration:
ClinicalTrials.gov NCT04178863.
More Related Videos
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Glaucoma: Overview