Related Experiment Video
Updated: Dec 10, 2025

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Changes in intracranial pressure and pulse wave amplitude during postural shifts
Nicolas Hernandez Norager1,2, Markus Harboe Olsen3, Casper Schwartz Riedel4,5
1Department of Neurosurgery, Rigshospitalet, Copenhagen, Denmark. nicolas.norager@gmail.com.
Background:
Monitoring of intracranial pressure (ICP) and ICP pulse wave amplitude (PWA) is an integrated part of neurosurgery. An increase in ICP usually leads to an increase in PWA. These findings have yet to be replicated during the positional shift from supine to upright, where we only know that ICP decreases. Our main aim is to clarify whether the positional shift also results in a change in pulse wave amplitude.
Method:
Our database was retrospectively reviewed for subjects having had a standardized investigation of positional ICP. In all subjects, mean ICP and PWA were determined with both an automatic and a manual method and compared using Student's t test. Finally, ICP and PWA were tested for correlation in both in supine and upright position.
Results:
The study included 29 subjects. A significant change in ICP (Δ14.1 mmHg, p < 0.01) and no significant change in PWA (Δ0.4 mmHg, p = 0.06) were found. Furthermore, a linear correlation between ICP and PWA was found in both supine and upright positions (p < 0.01).
Conclusions:
We found that during the positional shift from supine to upright, ICP is reduced while PWA remains unaffected. This indicates that the pressure-volume curve is shifted downward according to a hydrostatic pressure offset, while the slope of the curve does not change. In addition, the correlation between ICP and PWA in both supine and upright position validates the previous research on the matter.
More Related Videos
14:09Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
11:26Assessing Cerebral Autoregulation via Oscillatory Lower Body Negative Pressure and Projection Pursuit Regression
Published on: December 10, 2014
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Alterations in Blood Pressure
Hypertension (High blood pressure)
Hypertension occurs when blood pressure readings consistently exceed the normal range. It is diagnosed when systolic blood pressure (the top number, indicating pressure while the heart...
Sound as Pressure Waves
The pressure fluctuation depends on the difference in displacements between the successive points in the...
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement