Purpose:
Transcutaneous electrical stimulation (TES) is used to activate muscles when volitional capacity is impaired but potential benefits are limited by rapid force loss (fatigue). Most TES fatigue protocols employ constant-frequency trains, with stimuli at a fixed interstimulus interval (ISI); however, a brief ISI between the first two pulses (variable-frequency train, VFT) to maximize the catchlike property of muscle can attenuate fatigue development. The purpose of this study was to investigate if a VFT that simulates intrinsic variability of voluntary motor unit discharge rates would also mitigate fatigue, owing to the sensitivity of muscle to acute activation history.
Methods:
On two visits, 24 healthy adults (25.3 ± 3.7 years; 12 females) received 3 min of intermittent TES to the quadriceps of the dominant leg. Trains of eight pulses at 10 Hz were delivered with a constant (100 ms) or variable ISI (80-120 ms). Contractile impulse, rate of force development (RFD), and rate of relaxation (RFR) were determined for each tetanus RESULTS: During fatigue and recovery, contractile impulse did not differ between protocols (p ≥ 0.796) and sexes (p ≥ 0.493), with values of 77 ± 17% control at task end and 125 ± 19% control 2 min later. RFD and RFR also showed no effect of the protocol (p ≥ 0.310) or participant sex (p ≥ 0.119). Both measures slowed (38 ± 23% and 33 ± 22%, respectively) but dissociated during recovery as RFD remained 16 ± 18% below control at 5 min, whereas RFR recovered to control by 30 s (101 ± 22%).
Conclusion:
Contrary to expectations, the VFT protocol did not attenuate fatigue development, which suggests no benefit to mimicking the inherent variability of motor unit discharge rates.