Related Experiment Video
Updated: Dec 9, 2025

Thermal Imaging to Study Stress Non-invasively in Unrestrained Birds
Published on: November 6, 2015
Counterpoint to "Infrared cameras overestimate skin temperature during rewarming from cold exposure"
George Havenith1, Alex B Lloyd1
1Environmental Ergonomics Research Centre, School of Design and Creative Arts, Loughborough University, LE11 3TU, UK.
Abstract:
We evaluated the paper by Maley et al. (2020) in this journal "Infrared cameras overestimate skin temperature during rewarming from cold Exposure" for the evidence provided in support of its title and conclusions. Several methodological issues were identified as well as issues with the data interpretation: 1: Only one camera was used but a conclusion was made for 'cameras' in general; 2: The camera accuracy (±2 °C) is too low to do a meaningful comparison without using local reference values or an on-site calibrator with higher accuracy; 3: Thermistor measurements are taken as a gold standard while issues such as temperature gradients and taping are known; 4: Both methods are not compared at the same location and a natural, physiological, gradient may be present between their locations; 5. The impact of the sensor and tape on delays in the change of the underlying tissue temperature is not considered; 6: Only a single pixel was used for the analysis, which has been shown to be problematic. We concluded that the paper by Maley et al. does not provide conclusive evidence that infrared cameras overestimate skin temperature during rewarming from cold exposure.
Related Concept Videos
Decreased Body Temperature
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Thermosensation
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...