Highly Accelerated Real-Time Free-Breathing Cine CMR for Patients With a Cardiac Implantable Electronic Device
Sungtak Hong1, KyungPyo Hong2, Austin E Culver1
1Department of Radiology, Northwestern University Feinberg School of Medicine, 737 N. Michigan Avenue, Suite 1600, Chicago, IL 60611.
Rationale And Objectives:
To develop a 16-fold accelerated real-time, free-breathing cine cardiovascular magnetic resonance (CMR) pulse sequence with compressed sensing reconstruction and test whether it is capable of producing clinically acceptable summed visual scores (SVS) and accurate left ventricular ejection fraction (LVEF) in patients with a cardiac implantable electronic device (CIED).
Materials And Methods:
A 16-fold accelerated real-time cine CMR pulse sequence was developed using gradient echo readout, Cartesian k-space sampling, and compressed sensing. We scanned 13 CIED patients (mean age = 59 years; 9/4 males/females) using clinical standard, breath-hold cine and real-time, free-breathing cine. Two clinical readers performed a visual assessment of image quality in four categories (conspicuity of endocardial wall at end diastole, temporal fidelity of wall motion, any artifact level on the heart, noise) using a five-point Likert scale (1: worst; 3: clinically acceptable; 5: best). SVS was calculated as the sum of 4 individual scores, where 12 was defined as clinical acceptable. The Wilcoxon signed-rank test was performed to compare SVS, and the Bland-Altman analysis was conducted to evaluate the agreement of LVEF.
Results:
Median scan time was 3.7 times shorter for real-time (3.5 heartbeats per slice) than clinical standard (13 heartbeats per slice, excluding nonscanning time between successive breath-hold acquisitions). Median SVS was not significantly different between clinical standard (15.0) and real-time (14.5). The mean difference in LVEF was -2% (4.7% of mean), and the limits of agreement was 5.8% (13.5% of mean).
Conclusion:
This study demonstrates that the proposed real-time cine method produces clinically acceptable SVS and relatively accurate LVEF in CIED patients.
More Related Videos
10:17Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...