Objectives:
The aim of this study is to propose and evaluate a new method of volumetric perfusion computed tomography (PCT) incorporated into pancreatic multiphasic contrast enhanced (CE)-CT in the clinical setting.
Methods:
In this ethically approved study, PCT was incorporated into our existing scanning protocol in 17 patients and effective doses related to PCT were evaluated. CT values and signal-to-noise ratio (SNR) of anatomical structure were compared in diagnostic images that were acquired using 320-detector volumetric scan mode and 64-detector helical scan mode. In addition, focal lesion depiction was qualitatively assessed in the two groups. Perfusion parameters in normal pancreas were measured by two radiologists and the interobserver-reliability was assessed.
Results:
The effective dose of PCT was 5.1 ± 0.3 mSv. The actual effective dose (AED) including the dose used in volumetric scans for diagnostic imaging was 22.8 ± 5.3 mSv and the putative effective dose (PED) was 21.9 ± 9.1 mSv on average. There was no significant difference between AED and PED (p = 0.404). Compared with conventional helical scans, volumetric scans did not decrease CT values or SNR, but rather significantly increased those of the aorta in the arterial phase. Both groups had acceptable qualitatively assessed image quality with no significant difference in the depiction of each structure. There was almost perfect interobserver agreement in the measurement of perfusion parameters (mean ICCs > 0.9).
Conclusions:
Our scanning protocol for pancreatic perfusion CT provides high-quality images while requiring lower radiation doses than conventional methods.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET