Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

6.1K
Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
6.1K
Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

1.2K
In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
1.2K
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

3.3K
Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
3.3K
Supercritical Fluid Chromatography01:18

Supercritical Fluid Chromatography

662
Supercritical fluid chromatography (SFC) provides a beneficial substitute for gas chromatography (GC) and liquid chromatography (LC) for certain samples because it merges the top attributes of both techniques. SFC allows the separation and analysis of compounds that GC or LC does not easily manage. These compounds are traditionally nonvolatile or thermally unstable, making GC unsuitable and lacking functional groups required for HPLC analysis.
SFC utilizes a supercritical fluid mobile phase,...
662
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

851
Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
851
Gas Chromatography: Overview of Detectors01:13

Gas Chromatography: Overview of Detectors

1.5K
Detectors in gas chromatography (GC) help identify and quantify the components of a mixture by translating chemical properties into measurable signals, which are displayed on a chromatogram. Detectors can be categorized into two main types: destructive and non-destructive.
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
1.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A Sub-Milliwatt Graphene-Based Thermal Conductivity Detector for On-Site Gas Analysis.

Sensors (Basel, Switzerland)·2026
Same author

A MEMS Microbolometer-Based ATR Mid-Infrared Sensor for Direct Dissolved CO<sub>2</sub> Detection and UV-Induced Sediment Carbon Assay in Aquatic Environments.

Sensors (Basel, Switzerland)·2026
Same author

Controlling Cell Migratory Patterns Under an Electric Field Regulated by a Neural Network-Based Feedback Controller.

Bioengineering (Basel, Switzerland)·2025
Same author

A modular fluorescent camera unit for wound imaging.

Communications biology·2025
Same author

A bioelectronic device for electric field treatment of wounds reduces inflammation in an in vivo mouse model.

PloS one·2024
Same author

A pro-reparative bioelectronic device for controlled delivery of ions and biomolecules.

Wound repair and regeneration : official publication of the Wound Healing Society [and] the European Tissue Repair Society·2024

Related Experiment Video

Updated: Dec 9, 2025

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
11:44

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry

Published on: March 6, 2016

9.7K

Isomer separation enabled by a micro circulatory gas chromatography system.

Hao-Chieh Hsieh1, Hanseup Kim1

  • 1Electrical and Computer Engineering, University of Utah, Salt Lake City, UT 84112 United States.

Journal of Chromatography. A
|September 5, 2020
PubMed
Summary

Separating similar isomers like isopentane and pentane is challenging in micro gas chromatography. This study developed a micro circulatory gas chromatography (MCGC) system to achieve a 12.5-meter effective column length for isomer separation.

More Related Videos

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
04:56

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells

Published on: October 23, 2018

6.9K
Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
14:42

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Published on: September 23, 2021

5.5K

Related Experiment Videos

Last Updated: Dec 9, 2025

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
11:44

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry

Published on: March 6, 2016

9.7K
In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells
04:56

In Vitro Method to Control Concentrations of Halogenated Gases in Cultured Alveolar Epithelial Cells

Published on: October 23, 2018

6.9K
Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
14:42

Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems

Published on: September 23, 2021

5.5K

Area of Science:

  • Analytical Chemistry
  • Chemical Engineering
  • Separation Science

Background:

  • Separating structural isomers with similar properties is a significant challenge in analytical chemistry.
  • Microfabricated gas chromatography (GC) systems face limitations in column length due to low-pressure micropump capabilities.
  • Effective isomer separation requires advanced chromatographic techniques and system designs.

Purpose of the Study:

  • To demonstrate the separation of structural isomers (isopentane and pentane) using a novel micro circulatory gas chromatography (MCGC) system.
  • To overcome the limitations of short column lengths in microfabricated GC systems.
  • To achieve a long effective column length under low-pressure conditions.

Main Methods:

  • Development of a micro circulatory gas chromatography (MCGC) system utilizing a circulatory loop of two 25-cm micro open tubular columns.
  • Operation of the MCGC system under a minimal pressure requirement of less than 10 kPa.
  • Circulation of isomer gases for 25 cycles to achieve an extended effective column length.

Main Results:

  • Successful separation of isopentane and pentane, a pair of structural isomers.
  • Achieved an effective column length of 12.5 meters, the longest reported for any microfabricated GC system.
  • Demonstrated isomer separation capability at low operating pressures (<10 kPa).

Conclusions:

  • The developed MCGC system effectively separates structural isomers by creating a significantly long effective column length.
  • This approach overcomes the typical column length constraints in microfabricated GC systems.
  • The MCGC system offers a promising solution for isomer analysis in miniaturized chromatographic devices.