Ergonomic mastectomy bra design: Effect on core body temperature and thermal comfort performance
Kaoru Leung1, Kristina Shin1, Fred Han2
1Institute of Textiles and Clothing, The Hong Kong Polytechnic University, Hong Kong, China.
Abstract:
The accumulation of sweat and heat between the skin and the prosthesis is one of the common causes of discomfort experienced by post-mastectomy women who wore silicone-type external breast prostheses. This study aimed 1) to investigate the effect of a newly designed heat-reduction mastectomy bra on the thermal responses and thermal comfort performance; and 2) to propose an evaluation protocol for post-mastectomy products. The heat-reduction bra and the conventional bra were made of the same textile materials but the cup of the bra under discussion had a polyurethane cup with a perforated structure along the breast root/inframammary fold. The inframammary fold is often aggravated by heat, sweat, maceration, chafe, and lack of air circulation. Nine healthy male participants were recruited to participate in the study since the women who had undergone double-mastectomy were sensitive about their scars. An ingestible telemetric pill sensor was used to collect the data of core body temperature. Participants performed a 70-min five-phase exercise protocol wearing the heat-reduction bra and the conventional bra together with a silicone prosthesis with ventilation holes on the bottom. Physiological responses (i.e., core body temperature, skin temperature, temperature between bra and prosthesis, skin humidity and humidity between bra and prosthesis) and subjective sensation responses were measured. The results were statistically significant and the conventional mastectomy bra showed a higher core body temperature than that of the heat-reduction mastectomy bra (37.3 ± 0.3 °C to 38.2 ± 0.5 °C vs. 37.2 ± 0.3 °C to 38.0 ± 0.3 °C) starting from the middle of the sitting phase to the running phase and post-exercise resting (F = 164.2, p < 0.001). Both factors, the bra and the phase, have significant effects on the core body temperature (F = 14.5, p < 0.001). The heat-reduction mastectomy bra demonstrated optimum thermal comfort performance in both the temperature and humidity than the conventional mastectomy bra.
More Related Videos
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Factors Affecting Body Temperature
Factors may include:
Thermoregulation
Thermal Stress
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Decreased Body Temperature